formepaster.blogg.se

How to write collated file for res2dinv
How to write collated file for res2dinv







  1. #How to write collated file for res2dinv manual
  2. #How to write collated file for res2dinv full
  3. #How to write collated file for res2dinv software

Gradient array (only used as sub-array number with data in the general array format) Offset pole-dipole (only used as sub-array number with data in the general array format)Ĭross-borehole survey (apparent resistivity values)Ĭross-borehole survey (resistance values) The RES2DINV program will automatically convert a Wenner beta array data file into a dipole-dipole array data set.Ī list of the arrays supported by the RES2DINV program together with their number codes are given below. The Wenner beta array is a special case of the dipole-dipole array where the "n" factor is always 1. The "normal" Wenner array is actually the Wenner alpha array. The Wenner array has three different variations (Figure A.1).

how to write collated file for res2dinv

In general for an array with four electrodes, there are three possible arrangements for the electrodes. Table A.1 shows the arrangement of the electrodes, names and codes for some commonly used arrays.

how to write collated file for res2dinv

#How to write collated file for res2dinv full

Therefore, the Table and Figure numbering was kept constant with originals, which can be downloaded as full PDFs from the attachment to this blog post.Ī description of the different arrays types is given in the free tutorial notes on electrical imaging (Loke, 2011).

#How to write collated file for res2dinv manual

Information below is compiled from RES2DINV Manual and Loke’s Course Notes to facilitate data file preparation and usage in RES2DINV for beginners. The general array format can be used for any array, including gradient and non-conventional arrays of any configuration. The older index based format is only used for conventional arrays such as the Wenner, Wenner-Schlumberger, pole-pole, pole-dipole and dipole-dipole arrays. There are two main types of data format used by RES2DINV, an index based and a general array format. If there is a problem in running RES2DINV software, one possible cause is that the input data were arranged in a wrong format. You can use any general purpose text editor, such as the Windows Notepad program if you are creating the data file manually. The data are arranged in an ASCII delimited manner where a comma or blank space or LF/CR is used to separate different numerical data items.

#How to write collated file for res2dinv software

The apparent resistivity values (and IP) used by RES2DINV software are given in a text file with. Besides normal surveys carried out with the electrodes on the ground surface, the program also supports aquatic and cross-borehole surveys. You can process pseudo sections with up to 16000 electrode positions and 70000 data points at a single time on a computer with 4 gigabytes (GB) of RAM.

how to write collated file for res2dinv

In addition to these common arrays, the program even supports non-conventional arrays with an almost unlimited number of possible electrode configurations (Loke et al. RES2DINV program can be used for surveys using the Wenner, pole-pole, dipole-dipole, pole-dipole, Wenner-Schlumberger, gradient and equatorial dipole-dipole (rectangular) arrays. However, the program can also handle data sets with a non-uniform electrode spacing. The survey is usually carried out with a system where the electrodes are arranged along a line with a constant spacing between adjacent electrodes. This program is designed to invert large data sets (with about 200 to 100000 data points) collected with a system with a large number of electrodes (about 25 to 16000 electrodes). Many different multi-electrode systems have been developed over the past 15 years using different arrangements of the cables and measurement strategies (Loke, 2011). Example of electrodes arrangement and measurement sequence that can be used for a 2-D electrical imaging survey is shown on the left.









How to write collated file for res2dinv